Improt/Brand, minilec, Relay Sequence, Voltage Relay
minilec Phase Failure Relays VSP D2
minilec Phase Failure Relays VSP D2
Supply Voltage
- System100-120/220-240/380-440 V AC ± 20% 50/ 60 Hz
- Auxillary100-120/220-240/380-440 V AC ± 20%
Output Contacts
- Output Contacts2 CO
Trip Setting(Volts)
- Phase SequenceYes
- Phase Unbalance30 V to 70 V ± 6V (adjustable)
Trip Time Delay
SKU: n/a -
Controller, Relay Sequence, Safety Relay, SHIP BREAKING
Safety Relay Pilz PNOZ X3
Safety Relay Pilz PNOZ X3
Safety relay (standalone), inputs: 1/2-channel wiring with/without detection of shorts across contacts, outputs: 3 N/O, 1 N/C,1 SC, automatic/monitored start, UB = 24V AC/24 V DC, width: 45 mm, screw terminals integrated, monitoring of E-STOP, feedback loop, safety gates.SKU: n/a -
Automation, Electric, Frequency Relay , Power Supply
infineon ff300r13ke3 igbt 1200 V 300 A dual IGBT module
Automation, Electric, Frequency Relay , Power Supplyinfineon ff300r13ke3 igbt 1200 V 300 A dual IGBT module
infineon ff300r13ke3 igbt 1200 V, 300 A dual IGBT module
62 mm 1200 V, 300 A dual IGBT module with fast TRENCHSTOP™ IGBT3 and Emitter Controlled high-efficiency diode is the right choice for your design.
Configuration Dual Dimensions (width) 61.4 mm Dimensions (length) 106.4 mm Housing 62 mm IC(nom) / IF(nom) 300 A IC max 300 A Qualification Industrial Technology IGBT3 – T3 VCE(sat) (Tvj=25°C typ) 1.7 V VF (Tvj=25°C typ) 1.65 V Voltage Class max 1200 V SKU: n/a
-
MC/MAGNETIC CONTACTOR, Schneider, SHIP BREAKING
LC1D50 80A Schneider magnetic contactor
LC1D50 80A Schneider magnetic contactor
Manufacturers: Schneider
Sub-Category: Contactor
Family: TeSys D
Type: LC1D
Phase: 3
Poles: 3
Voltage: 110v/220v/440v
Amperage: 80
Coil Voltage Min: 220v
Coil Voltage Max: 230v
made in France
SKU: n/a -
-
-
ABB, MC/MAGNETIC CONTACTOR, SHIP BREAKING
ABB A50 magnetic contactor
ABB A50 magnetic contactor
ith 125A
Made in France
volt 220v/440v
Number of Main Contacts NO:3
Number of Main Contacts NC:0
Number of Auxiliary Contacts NO:1
Number of Auxiliary Contacts NC:1
A50 contactors are mainly used for controlling 3-phase motors and generally for controlling power circuits up to 690 V AC / 1000 V AC or 220 V DC
SKU: n/a -
MC/MAGNETIC CONTACTOR, SHIP BREAKING, Telemecanique
Telemecanique LC1D95 (125A)
LC1D95, Telemecanique, contactor LC1D95, TeSys D, type LC1D, 3P, 3PH, 125A, 600V, 30HP @ 240V, 60HP @ 480V, 60HP @ 600V, complete with 110/120V AC coil, and 1 N/O – 1 N/C auxiliary contact, AC magnetic contactor, suitable for use with LC1-D series motor control systems
SKU: n/a -
-
-
Automation, Electric, Frequency Relay , Power Supply
infineon ff300r13ke3 igbt 1200 V 300 A dual IGBT module
Automation, Electric, Frequency Relay , Power Supplyinfineon ff300r13ke3 igbt 1200 V 300 A dual IGBT module
infineon ff300r13ke3 igbt 1200 V, 300 A dual IGBT module
62 mm 1200 V, 300 A dual IGBT module with fast TRENCHSTOP™ IGBT3 and Emitter Controlled high-efficiency diode is the right choice for your design.
Configuration Dual Dimensions (width) 61.4 mm Dimensions (length) 106.4 mm Housing 62 mm IC(nom) / IF(nom) 300 A IC max 300 A Qualification Industrial Technology IGBT3 – T3 VCE(sat) (Tvj=25°C typ) 1.7 V VF (Tvj=25°C typ) 1.65 V Voltage Class max 1200 V SKU: n/a -
Automation, Controller, Frequency Relay
ROTARY ENCODER FA-CODER TAMAGAWA OIH 48-2500P8-L6 5V-215
ROTARY ENCODER FA-CODER TAMAGAWA OIH 48-2500P8-L6 5V-215
Model: 48-2500P8-L6-5V
48-2500P8-L6 Pulse: 2500c/t
Working temperature: 20-85
Shaft Diameter: 7.5-9.0mm
Working voltage: 5V
48-2500P8-L6 Signal Classification: Incremental
Humidity: 90% RH
SKU: n/a -
Over Load Relay, Relay, Schneider
Schneider overload relay lr9f7379 300-500A
Schneider overload relay lr9f7379 300-500A
Electronic thermal overload relay,TeSys Giga,125-500 A,class 5E-30E,push-in control connectioneSys LR9F electronic overload relay, thermal setting range 300-500A, class 10, for protection of motors 200-250kW@400V. to be mounted directly below a TeSys F 3-pole contactor LC1 F225, F265, F330, F400, F500, use of a support mounting plate LA7F902 is mandatory (to be ordered separately). Motor protection includes thermal overload of 1-phase and 3-phase motors, phase failure, phase unbalance, prolonged starting times, stalled rotor conditions. On the front of the relay, it provides a thermal adjustement dial, buttons for test, stop & reset, a trip indicator, trip auxiliary contacts 1NO+1NC. Multi standards certified (IEC, UL, CSA, CCC, Marine), Green Premium compliant (RoHs/Reach)SKU: n/a -
-