VSP-3 Phase Failure Relay
TECHNICAL SPECIFICATION:
Supply Voltage
Supply Voltage415 VAC ± 20%, 50 Hz ± 3%
Output Relay Contact
Output Relay Contact1 NO
Output Contact Rating
Output Contact Rating5 Amp, 240 VAC (RESISTIVE)
Unbalance Trip Setting
Unbalance Trip Setting50 V ± 10 VAC
Trip Time Delay For
For unbalance3.5 secs. ± 1.5 sec
Dry Run Setting
Dry Run SettingN.A.
On Time Delay
On Time DelayN.A.
Star-Delta Changeover Time Delay
Star-Delta Changeover Time DelayN.A.
Resetting
ResettingAuto Reset
Auto Switch
Auto SwitchN. A.
Enclosure
EnclosureHIP moulded
Dimensions (mm)
Overall103 x 66 x 43
Mounting91 x 48
Mounting
MountingPanel Mounting
Weight
Weight250gms
Level sensor
Quantity
Dimensions
Operating Conditions
Temperature-5 °C TO + 60 °C
HumidityUpto 95% Rh
Application
Suitable for 3 Ph. equipments
Agricultural Pump Starters.
3 Ph. Split AC machines.
Hoist Motor Control
Valve Actuator Motor
Machine Tools
Injection Molding M/c
There are no reviews yet.