Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the electro-extensions domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home/factorye/public_html/wp-includes/functions.php on line 6121

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the woocommerce domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home/factorye/public_html/wp-includes/functions.php on line 6121

Deprecated: Hook site-logo is deprecated since version 13.4! Use custom-logo instead. Jetpack no longer supports site-logo feature. Add custom-logo support to your theme instead: https://developer.wordpress.org/themes/functionality/custom-logo/ in /home/factorye/public_html/wp-includes/functions.php on line 6121
mk-05 phase failure and sequence relay - factoryelectric.com.bd
, , ,

mk-05 phase failure and sequence relay


MK 05 phase failure and sequence relay

MK-05, MKC-05, MK-06, and MKC-06 phase failure devices serve the following protection features.
1. Phase failure

2. Phase sequence

3.PTC Protection (only available in MK-05P,MKC-05P,MKC-06P,MK-06P Versions)

4.Voltage unbalance(Both unbalance and delay adjustable)

5. Insufficient supply

MK 05 phase failure and sequence relay

MK-05, MKC-05, MK-06, and MKC-06 phase failure devices serve the following protection features.
1. Phase failure

2. Phase sequence

3.PTC Protection (only available in MK-05P,MKC-05P,MKC-06P,MK-06P Versions)

4.Voltage unbalance(Both unbalance and delay adjustable)

5. Insufficient supply

Technical data:

1)Model no:MKC-06,MK-06,MK-06P,MKC-06P,MK-05,MKC-05,MK-05P,MKC-05P

2)Rated voltage(un):220VAC(For MK-05/05P,MKC-05/05P)

3 phase+neutral: 4 wires connection 120VAC

3 phase+neutral: 4 wires connection (MKC-05/05P Special design) 380VAC

3 phase: 3 wires connection ( For MK-06/06P, MKC-06/06P) 440VAC

3 phase: 3 wires connection ( For MKC-06/06P Special design)

The three-phase network being protected is used as the device power supply

3)Operating range: (0.9-1.1)xUn

4)Rated frequency: 50/60HZ

5)Output contact: 1 C/O with 8A, 2000VA(For resistive load)

6)Asymmetry range: 5%-15%, 3x380VAC

7)Tripping time: 0.1-10 sec. (Adjustable)

8)Phase sequence: available

9)Ambient temperature: -5°c~+50°c

10)Protection degree: IP20

11)Installation: Surface mounting or on the mounting rails